      Fluke 1621 KIT 12 Piece Earth Ground Tester Kit

      The Fluke 1621a is an easy-to-use earth ground tester. For ground resistance testing, the 1621 is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests. Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth ground tester, for most electrical grounding work environments. With a simple user interface and intuitive functionality, the Fluke 1621 is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists.

       

      Features

      -       Portable size allows for easy transportation

      -       Easily capture values with single-button operation

      -       Clearly read and record data with a large, backlit display

      -       3-pole Fall-of-Potential earth testing for basic measurements

      -       2-pole resistance measurements for added versatility

      -       Ensure accurate measurements with automatic ‘noise’ voltage detection

      -       Hazardous voltage warning offers increased user protection

      -       Rugged holster and design for tough work environments

      -       Instantly be alerted to measurements outside of your set limit, when you use the adjustable limit setting

      -       600 V Cat II

       

      Includes

      -       Fluke 1621 Tester

      -       2 cable reels with wire (1-50m, 1-25m)

      -       3 earth ground stakes

      -       1 Test lead (red and black 2m)

      -       2 Alligator Clips

      -       Batteries

      -       Users manual

      -       Hard carrying case

       

      General specifications

      Measuring functions

      3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage

      Intrinsic error

      Refers to the reference temperature range and is guaranteed for one year

      Measuring rate

      2 measurements/second

      Battery[1]

      One 9 volt alkaline (LR61)

      Battery condition

      LO-BAT is displayed if voltage drops below 6.5 V

      Voltages

      Between jacks H/C2 and E/C1: 250 Veff maximum (effective voltage)
      Between jacks S/P2 and E/C1: 250 Veff maximum

      Standard infrared lens type

      Field of view: 17° x 17°
      Spatial resolution: (IFOV) 2.50 mRad
      Minimum focus distance: 15 cm (approx. 6 in)

      Climatic class

      VDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87)

      Temperature performance[2]

      Working:

      -10 °C to +50 °C (+14 °F to +122 °F)

      Operating:

      0 °C to +35 °C (+32 °F to +95 °F)

      Storage:

      -20 °C to +60 °C (+68 °F to +140 °F)

      Reference:

      +23 °C ± 2 °C (+73 °F ± 4 °F)

      Temperature coefficient

      ± 0.1 % of range per degree Kelvin

      Safety

      IEC/EN 61010-1, 600 V CAT II, pollution degree 2

      Dimensions

      113 mm x 54 mm x 216 mm (4.5 in x 2.1 in x 8.5 in), including holster

      Weight

      850 g (1.9 lb), including standard accessories, volume approximately 600 cm3

      Note:

      [1]If the tester is not going to be used, or is being stored for a long period, remove the battery and store separately from the tester to avoid damage from battery leakage.
      [2]The four temperature ranges for the tester exists to satisfy European Standards requirements; the instrument can be used over the full working temperature range by using the temperature coefficient to calculate accuracy at the ambient temperature of use.

      Electrical specifications

      Maximum deviations:

      E1 Influence factor Position
      E1 Deviation influence 0 %
      E2 Influence factor Supply voltage
      E2 Deviation influence 0 %
      E3 Influence factor Temperature E3
      E3 Deviation influence 2.3 %
      E4 Influence factor Serial interference voltage (20 V)
      E4 Deviation influence 0.6 %
      E5 Influence factor Probe- and auxiliary probe resistance
      E5 Deviation influence 10 %

      Test voltage

      3.7 kV

      Protection type

      IP 40; IEC/EN 60529

      Electromagnetic compatibility

      Emission: IEC/EN 61326 Class B
      Immunity: IEC/EN 61326 Annex C

      RE resistance measurement

      Measuring method

      Current-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC/EN 61557-5

      Open circuit voltage

      23 to 24 V ac

      Short circuit current

      > 50 mA ac

      Measuring frequency

      128 Hz

      Maximum permissible Overload

      250 Veff

      Measuring time

      8 seconds (average from when START is pressed)

      Limit input

      Tester retains set value even if instrument is turned off (assuming battery power supply is sufficient)

      Automatic changeover of resolution

      RH < 7 k Ω
      Resolution 0.01 Ω
      RH < 50 kO
      Resolution 0.1 Ω
      RH > 50 kO
      Resolution 1 Ω

      Interference voltage display dc + ac

      Vmax 30 Veff
      Common mode rejection > 80 dB at 50 Hz and 60 HzM
      Ri 680 kO
      Measuring uncertainty < 10 % for pure ac and dc signals

      Measuring range

      0.15 Ω to 20 Ω

      Resolution 0.01 Ω
      Display range 0 to 19.99 Ω

      200 Ω

      Resolution 0.1 Ω
      Display range 20 to 199.9 Ω

      2 k Ω

      Resolution 1 Ω
      Display range 200 to 1999 Ω

      Intrinsic uncertainty

      ± (6 % Ωf measured value + 5D)

      Operating uncertainty IEC 61557[1]

      ± (18 % Ωf measured value + 5D)

      Notes:

      [1] Covers all deviations caused by influence quantities E1-E5. If the deviation E4 caused by high probe Ωr auxiliary probe resistance is higher than specified flashes. Measured values are Ωutside Ωf the specified Ωperating uncertainty

       

       